Google Plus Facebook Twitter Linkedin YouTube PinInterest     Feedburner
Home   |   Query   |   Courses   |   Career  Press  Gallery   |   Contact

Medical tourism

Overseas Patients click here

Experience Kolkata (City of Joy) along with superlative dentalcare

more »

 

Follow Aesthetica Cliniq on


 

Hygienic Treatment Practices

Hygienic treatment environment and practices are very important when it comes to maintaining patient care standards. As per one survey dental clinics are generating more than half kilogram bio-medical waste everyday which can be very infectious.
 
Strict infection control and proper sterilization are vital for providing hygienic treatment practices.
 
Our quality protocols:
 
1. We use only Reverse Osmosis treated water for all our patients.
 
2. We use disposable gloves, mask, needles and glasses for each patient.
 
3. We adhere to standard protocols of instrument sterilisation and maintain complete hygiene, sterilised instruments are stored in appropriate pouches/cabinets to maintain sterility.
 
4. A team of super specialists offer the highest quality of dental care across all branches of dentistry.
 
5. The clinical waste generated from our clinic is disposed as per strict local civic norms. Disposable needles are discarded by a burning process as per WHO norms.
 
6. Our clinic is equipped with a digital intra-oral camera so that you yourself can exactly see and understand your dental problems.
 
7. The digital RVG X-ray used in our clinic reduces the radiation exposure to the patient by 90%.
 
8. A dedicated paediatric dental section provides soothing dental care in a child friendly atmosphere.
 
9. We do not use mercury based silver fillings in our clinic as they have shown to be harmful.
 
10. State-of-the art digital OPG machine (the only super-speciality centre in eastern India to have this facility) ensures that all your diagnostic needs are addressed under one roof.
 
11. A customised family Privilege Card has been introduced so that you and your family can avail international quality dental treatments at discounted rates round the year.

 

Infection Control
 
We are aware of the hazards of cross contamination in the dental clinic and take all possible precautions for your safety as well as our.
 

 
All possible materials are disposed, including gloves, glasses, suction tips etc.
 
All precautions are taken, where AIDS and Hepatitis are concerned.

 

Sterilization Safety
 
With a number of infectious diseases cropping up and (dreaded AIDS) on a rise, we understand the need for strict infection control and sterilization. Our practice takes stringent measures to minimize the risk of infection. Complete sterilization cannot be achieved by simply boiling instruments in water.
 
At Aesthetica, we achieve foolproof sterilization of all instruments by putting them through two stages of sterilization. In the first stage, the instruments are cleaned using Ultrasonic instruments, chemi-claved or cold sterilized with anti-bacterial, fungal, viral and surface disinfectants.
 
In the second stage the instruments are autoclaved. That is, the instruments are subjected to steam treatment at a pressure of 20 PSI at 130 degree Celsius for at least 15 minutes. Before autoclaving, sterilization authentication strips are placed in the autoclave along with the instruments. These strips change colour only when complete Our quality sterilization is achieved. We keep these strips as a record after the autoclaving process is over and the patient has a right to ask for and check them for proof of complete sterilization.
Á
sterilization is achieved. We keep these strips as a record after the autoclaving process is over and the patient has a right to ask for and check them for proof of complete sterilization.

 

A set of sterilized instruments for each patient
 
Treatment at Dental Designs is by prior appointment only. This ensures that each patient has a completely sterilized set of instruments ready for him.

 

Use of disposables
 
Following standard international procedures for infection control, single-use disposables are used wherever possible; for example hand gloves for surgeons and assistants, suction tips, injection needles, etc. In addition, we use single use disposable wrappers to cover all areas where the doctor is likely to come into contact with. For e.g. dental tray handles, 3-way syringes, etc.
 
After each sitting, surface disinfectants are used to disinfect all possible areas of contamination. In short, we consciously keep the whole dental environment in a state of continuous asepsis.

 

Radiation Safety
 
Latest digital radiographic machine and RVG system from satelec is used in the clinic, by this we can reduce the amount of radiation to almost 1/4th for diagnostic x-rays. X-ray units have been under the scrutiny of both infection control as well as Radiation Hazards. Dental clinic and centre take utmost care to protect you both from radiation hazards as well as follow strict asepsis procedure. A sterile disposable plastic packet is used for each X-Ray examination. These measures are carried out rigorously and consistently and demonstrate our commitment to your safety. Your safety and protection is our motto.

 
SL.NO ITEM STEP - I STEP - II STEP - III
1 Examination sets Brush & soap   Autoclave
2 Burs (diamond &carbide) Brush & soap Ultrasonic cleaner Cidex
3 Rct files Brush & soap Ultrasonic cleaner Autoclave
4 Implants drills Brush & soap Ultrasonic cleaner Autoclave
5 Extraction instruments Brush & soap   Autoclave
6 Hand – pieces Wipe with alcohol swab after each use   Autoclave (for implants & impaction cases only)
7 Stainless steel instruments Brush & soap   Cidex
8 Bracket tables Wipe with alcohol swab after each use    
9 Dental chairs Wipe with alcohol swab after each use   Bacillol spray and wipe
10 Visible blood or pus on any surface Clean & disinfect with 0.5% sodium hypochloride rinse.    
11 Carrier trays Wipe with alcohol swab after each use    
12 Detachable 3 way syringe Brush & soap   Autoclave (with the first batch in morning)
13 Ultrasonic scaler & tips Brush & soap   Autoclave
14 Syringes (2ml, 10ml)     Disposable
15 Needles     Disposable
16 Suction tips     Disposable
17 Prophylactic brushes     Disposable
18 Metal suction tips Brush & soap   Autoclave
19 Rvg sensor     Change sleeve after every use
20 Gloves     Disposable
21 Glass slab Wipe with alcohol swab after each use   Autoclave
LINK EXCHANGE     |      DISCLAIMER     |      SITEMAP